Method of control

  • manually – by handle
  • electrically – by remote control unit or the switch

Guaranteed dimensions

  • minimum width: 600 mm
  • maximum width: 4,000 mm (for handle control) / 6,000* mm (for motor control)
  • maximum height: 4,000 mm
  • maximum area: 8 m2 (for handle control) / 24 m2 (for motor control)

* Note: The wider the blind, the lower its wind resistance class – see Wind resistance, further down the page.

Non-standard dimensions are not produced..

Technical parameters

Head rail Bottom rail Slat Side guiding Ladder Textile strip
Business name
Dimensions [mm]
Material
P001
56 × 58
Fe
63278
P001/2
56 × 60
Al
63278
P 012/1
93 × 14
Al
63279
S37/2
0,42 × 113
Al
63277
Guiding bar S029/1
86 × 9,5
PES
S029/21
PES
P 028
8 × 0,34
PES
Colour Standard: galvanized sheet natural (Al profile)
Other RAL in spraying
Standard: elox. aluminium
Other RAL by spraying
According to the actual sample of ISOTRA a.s. Standard: elox
Other RAL by spraying
grey grey

Colours

62539

Basic RAL colours for Setta 90 slat

RAL colours for slat at extra charge

Colour performance Isotra System Decoral 1 at extra charge (cover box, guiding rail, guiding rail holder, head + bottom rail)

Colour performance Isotra System Decoral 2 at extra charge (cover box, guiding rail, guiding rail holder, head + bottom rail)

 

Hereby stated colors are only indicative. If you want to see the color in real we recommend to visit one of our business partners where you can ask for physical swatch. We cannot accept claims for inappropriately chosen color according to electronic sampler.

Assembly options

Basic types of assembly

  • Assembly into created pocket (ceiling / wall)
  • Assembly into reveal on the window frame (ceiling / wall)
  • Assembly on the expanding profile of the window (ceiling / wall)

Assembly into created pocket (ceiling / wall) Assembly into reveal on the window frame (ceiling / wall) Assembly on the expanding profile of the window (ceiling / wall)

These three types of assembly can be in two versions: cover box cold-wet/ cover box incorporated into heat-insulation system or peripheral shell.

Specific assembly

  • Self-bearing version (fixation of the blind on guiding bars)
  • Façade version (round cassette; assembly on the facade)
  • Assembly into Heluz bresummer (built-in guiding bars)
  • Assembly into Porotherm bresummer (recommended for independent construction)
  • The self-supporting blind with packet of slats outside the head rail

It is necessary to consider assembly into the bresummer in the design phase for a family home

The self-supporting blind with packet of slats outside the head rail Bravo

Guaranteed dimensions for Setta 90 blinds Bravo

  • minimum width: 600 / 720* mm
  • maximum width: 3,500 / 1,800* mm
  • maximum height: 2,700 / 2,500* mm
  • maximum area: 9 m2 / 3* m2

*design with insect screen
Note: The maximum height of blind, which the box of 210 mm is suitable for.

The self-supporting blind Viva

Guaranteed dimensions for Setta 90 blinds Viva

  • minimum width: 600 / 720* mm
  • maximum width: 3,500 / 1,800* mm
  • maximum height: 3,000 / 2,500* mm
  • maximum area: 9 m2 (for motor control)  / 3* m2

*design with insect screen
Note: The maximum height of blind, which the box of 300 mm is suitable for.

Setta 90 into a lintel

Guaranteed dimensions for Setta 90 blinds into a lintel

  • minimum width: 600 mm
  • maximum width: 3,850 mm
  • maximum height: 1,900 mm
  • maximum area: 8 m2

Wind resistance

Wind resistance tests performed by the Center of building engineering in Zlín according to ČSN EN 13659.

Guiding channel

Essential characteristics Performance
Wind resistance Width of construction hole L (mm) L <= 2 000  2 000 < L <= 3 000 3 000 < L <= 4 000 4 000 < L <= 4 500
Standard EN/Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort
Wind resistance class 5 8 4 7 2 5
Max. wind speed vmax (km/h)  74  61  49  38
Max. effective height wing  Hmax = 4000 mm
Width of construction hole L (mm) 4 500 < L <= 5 000  5 000 < L <= 5 500 5 500 < L <= 5 800 5 800 < L <= 6 000
Wind resistance class 1 4  0 3 0 2 0 1
Max. wind speed vmax (km/h) 28 19 11 5
Max. effective height wing Hmax = 4000 m
Additional thermal resistance ΔR 0,08 (m2.K/W)
Total solar energy transmittance gtot 0,032 - 0,094 (according to chosen slat colour)*

Guiding rope

Essential characteristics Performance
Width of construction hole L (mm) L <= 2 000 2 000 < L <= 3 000 3 000 < L <= 4 000  4 000 < L <= 4 500 4 500 < L <= 4 800 4 800 < L <= 5 000 5 000 < L <= 6 000
Standard EN/Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort
Wind resistance class 3 6 2 5 1 4 0 3 0 2 0 1 0 0
Max. wind speed vmax (km/h)  49  38  28 19 11 5 1
Max. effective height wing Hmax = 2500 mm
Width of construction hole L (mm) L <= 2 000 2 000 < L <= 3 000 3 000 < L <= 4 000 4 000 < L <= 4 500 4 500 < L <= 4 800 4 800 < L <= 5 000 5 000 < L <= 6 000
Wind resistance class 2 5 1 4 0 3 0 2 0 1 0 0 0 0
Max. wind speed vmax (km/h) 38  28 19 11 5 1 0
Max. effective height wing Hmax = 4000 mm
Additional thermal resistance ΔR 0,08 (m2.K/W)
Total solar energy transmittance gtot 0,032 - 0,094 (according to chosen slat colour)*

Method of control

  • manually – by handle
  • electrically – by remote control unit or the switch

Guaranteed dimensions

  • minimum width: 600 mm
  • maximum width: 4,000 mm (for handle control) / 6,000* mm (for motor control)
  • maximum height: 4,000 mm
  • maximum area: 8 m2 (for handle control) / 24 m2 (for motor control)

* Note: The wider the blind, the lower its wind resistance class – see Wind resistance, further down the page.

Non-standard dimensions are not produced..

Technical parameters

Head rail Bottom rail Slat Side guiding Ladder Textile strip
Business name
Dimensions [mm]
Material
P001
56 × 58
Fe
63278
P001/2
56 × 60
Al
63278
P 012/1
93 × 14
Al
63279
S37/2
0,42 × 113
Al
63277
Guiding bar S029/1
86 × 9,5
PES
S029/21
PES
P 028
8 × 0,34
PES
Colour Standard: galvanized sheet natural (Al profile)
Other RAL in spraying
Standard: elox. aluminium
Other RAL by spraying
According to the actual sample of ISOTRA a.s. Standard: elox
Other RAL by spraying
grey grey

Colours

62539

Basic RAL colours for Setta 90 slat

  • 1015 1015
  • 3000 S 3000 S
  • 5014 5014
  • 7016 7016
  • 7035 7035
  • 7038 7038
  • 7048 7048
  • 8014 8014
  • 9005 9005
  • 9006 9006
  • 9007 9007
  • 7022 7022
  • 9010 9010
  • 9016 9016
  • DB 703 DB 703
  • VSR 780 VSR 780

RAL colours for slat at extra charge

  • 3004 3004
  • 5002 5002
  • 6005 6005
  • 9002 9002
  • DB 702 DB 702
  • W 210 W 210

Colour performance Isotra System Decoral 1 at extra charge (cover box, guiding rail, guiding rail holder, head + bottom rail)

  • ISD110 ISD110
  • ISD120 ISD120
  • ISD130 ISD130
  • ISD140 ISD140
  • ISD150 ISD150
  • ISD160 ISD160
  • ISD210 ISD210
  • ISD220 ISD220
  • ISD230 ISD230
  • ISD310 ISD310
  • ISD152 ISD152
  • ISD154 ISD154
  • ISD200 ISD200
  • ISD212 ISD212
  • ISD214 ISD214
  • ISD222 ISD222

Colour performance Isotra System Decoral 2 at extra charge (cover box, guiding rail, guiding rail holder, head + bottom rail)

  • ISD500 ISD500
  • ISD510 ISD510
  • ISD600 ISD600
  • ISD610 ISD610
  • ISD620 ISD620
  • ISD630 ISD630
  • ISD640 ISD640
  • ISD700 ISD700
 

Hereby stated colors are only indicative. If you want to see the color in real we recommend to visit one of our business partners where you can ask for physical swatch. We cannot accept claims for inappropriately chosen color according to electronic sampler.

Assembly options

Basic types of assembly

  • Assembly into created pocket (ceiling / wall)
  • Assembly into reveal on the window frame (ceiling / wall)
  • Assembly on the expanding profile of the window (ceiling / wall)

Assembly into created pocket (ceiling / wall) Assembly into reveal on the window frame (ceiling / wall) Assembly on the expanding profile of the window (ceiling / wall)

These three types of assembly can be in two versions: cover box cold-wet/ cover box incorporated into heat-insulation system or peripheral shell.

Specific assembly

  • Self-bearing version (fixation of the blind on guiding bars)
  • Façade version (round cassette; assembly on the facade)
  • Assembly into Heluz bresummer (built-in guiding bars)
  • Assembly into Porotherm bresummer (recommended for independent construction)
  • The self-supporting blind with packet of slats outside the head rail

It is necessary to consider assembly into the bresummer in the design phase for a family home

The self-supporting blind with packet of slats outside the head rail Bravo

Guaranteed dimensions for Setta 90 blinds Bravo

  • minimum width: 600 / 720* mm
  • maximum width: 3,500 / 1,800* mm
  • maximum height: 2,700 / 2,500* mm
  • maximum area: 9 m2 / 3* m2

*design with insect screen
Note: The maximum height of blind, which the box of 210 mm is suitable for.

The self-supporting blind Viva

Guaranteed dimensions for Setta 90 blinds Viva

  • minimum width: 600 / 720* mm
  • maximum width: 3,500 / 1,800* mm
  • maximum height: 3,000 / 2,500* mm
  • maximum area: 9 m2 (for motor control)  / 3* m2

*design with insect screen
Note: The maximum height of blind, which the box of 300 mm is suitable for.

Setta 90 into a lintel

Guaranteed dimensions for Setta 90 blinds into a lintel

  • minimum width: 600 mm
  • maximum width: 3,850 mm
  • maximum height: 1,900 mm
  • maximum area: 8 m2

Wind resistance

Wind resistance tests performed by the Center of building engineering in Zlín according to ČSN EN 13659.

Guiding channel

Essential characteristics Performance
Wind resistance Width of construction hole L (mm) L <= 2 000  2 000 < L <= 3 000 3 000 < L <= 4 000 4 000 < L <= 4 500
Standard EN/Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort
Wind resistance class 5 8 4 7 2 5
Max. wind speed vmax (km/h)  74  61  49  38
Max. effective height wing  Hmax = 4000 mm
Width of construction hole L (mm) 4 500 < L <= 5 000  5 000 < L <= 5 500 5 500 < L <= 5 800 5 800 < L <= 6 000
Wind resistance class 1 4  0 3 0 2 0 1
Max. wind speed vmax (km/h) 28 19 11 5
Max. effective height wing Hmax = 4000 m
Additional thermal resistance ΔR 0,08 (m2.K/W)
Total solar energy transmittance gtot 0,032 - 0,094 (according to chosen slat colour)*

Guiding rope

Essential characteristics Performance
Width of construction hole L (mm) L <= 2 000 2 000 < L <= 3 000 3 000 < L <= 4 000  4 000 < L <= 4 500 4 500 < L <= 4 800 4 800 < L <= 5 000 5 000 < L <= 6 000
Standard EN/Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort 13659 Beaufort
Wind resistance class 3 6 2 5 1 4 0 3 0 2 0 1 0 0
Max. wind speed vmax (km/h)  49  38  28 19 11 5 1
Max. effective height wing Hmax = 2500 mm
Width of construction hole L (mm) L <= 2 000 2 000 < L <= 3 000 3 000 < L <= 4 000 4 000 < L <= 4 500 4 500 < L <= 4 800 4 800 < L <= 5 000 5 000 < L <= 6 000
Wind resistance class 2 5 1 4 0 3 0 2 0 1 0 0 0 0
Max. wind speed vmax (km/h) 38  28 19 11 5 1 0
Max. effective height wing Hmax = 4000 mm
Additional thermal resistance ΔR 0,08 (m2.K/W)
Total solar energy transmittance gtot 0,032 - 0,094 (according to chosen slat colour)*

Download

Are you interested in this product? Do you have any questions?

We would like to answer your questions, please fill in the form below and we will respond within 3 working days.



captcha

By sending this enquiry you agree with the sending of the business notifications of the company according to the provision of Section 7 of Act
No 480/2004 Coll., as amended, to the electronic address of the sender. The sender of this message takes into consideration that he/she is entitled to recall
this consent at anytime in the future either for the receipt of this message, as well as the receipt of business notifications.