Cetta 80, Cetta 80 Flexi external aluminium blinds
The most popular blind for outdoor shading is the Cetta 80 blind. Due to its appearance, it is particularly recommended for family homes. The slats are “C” shaped with a width of 8 cm. The Cetta outdoor blind is characterized by the extensive variability of the construction. The Flexi and Slim versions have a lower roll height and the Duo version is characterized by the level of tilting of the upper and lower part of the blind at the same time.
The Cetta 80 blind, which has folders along the whole length of the slat, is more stable in the wind and resistant against pressure. For offices and conference rooms we recommend the DUO system where the upper and lower part of the blind are tilted in a different way. Aluminium guiding bars ensure stability of the blind in wind and are a supporting element for securing the house against burglary.
The exterior shading technology creates an optimal environment in terms of lighting and thermal conditions and is a key part of the construction in terms of energy savings. In the traditional concept, exterior shading fulfils the shading and security function, whereas in the non-traditional concept, they are an architectonic element of administrative buildings and adorn family houses.
Advantages and benefits
- lower profile from the extruded aluminium
- variability of the Duo construction system, Slim system, Flexi system,
- high level of shading
- thermoregulation and protective effect
- decrease of the level of outside noise
- electric control option
- guaranteed area of up to 24 m2.
References
Manner of control
- manually – by handle
- electrically – by remote control unit or switch
Guaranteed dimensions
- minimum width: 600 mm
- maximum width: 4,000 mm (for handle control, Cetta 80 Flexi – for motor control) / 6,000* mm (for motor control)
- maximum height: 4,000 mm
- maximum area: 8 m2 (for handle control) / 16 m2 (for Cetta 80 Flexi – for motor control) / 24 m2 (for motor control)
* Note: The wider the blind, the lower its wind resistance class – see Wind resistance, further down the page.
Non-standard dimensions are not produced.
Technical parameters
Drawing of Cetta 80
Upper profile | Lower profile | Lamella | Side Guidance | Ladder | Textile strip |
|||
---|---|---|---|---|---|---|---|---|
Steel Wire | Guiding Channel | |||||||
Business name Dimensions (mm) Material |
P 001 56 × 58 Fe ![]() |
P 001/2 58 × 60 Al ![]() |
P 012/3 80 × 13 Al ![]() |
P 040 0,42 × 98 Al ![]() |
P 36, P 36 9004 ø 3,2 Fe/PVC |
See Technical Manual | P 030/1 72 × 85 PES |
P 531, P531/1 6 × 0,28 PES |
Colour | Standard: galvanized steel plate natural (Al profil) Other RAL colors sprayed, DECORAL* |
Standard: anodized aluminum Other RAL colors sprayed, DECORAL* |
According to current ISOTRA a.s. scheme |
grey black |
Standard: |
grey black |
grey black |
*maximum dimension 4000 mm
Colours
Basic RAL colours for Cetta 80 lamellas
-
1015
-
3000 S
-
5014
-
7016
-
7035
-
7038
-
7048
-
8014
-
9005
-
9006
-
9007
-
7022
-
9010
-
9016
-
DB 703
-
VSR 780
RAL colours for Cetta 80 lamellas are at an extra charge
-
3004
-
5002
-
6005
-
9002
-
DB 702
-
W 210
Basic RAL colours for Cetta 80 – Flexi lamellas
-
7022
-
9006
-
9007
-
9016
RAL colours for Cetta 80 – Flexi lamellas are at an extra charge
-
7016
-
VSR 780
Colour performance Isotra System Decoral 1 at extra charge (cover box, guiding rail, guiding rail holder, head + bottom rail)
-
ISD110
-
ISD120
-
ISD130
-
ISD140
-
ISD150
-
ISD160
-
ISD210
-
ISD220
-
ISD230
-
ISD310
-
ISD152
-
ISD154
-
ISD200
-
ISD212
-
ISD214
-
ISD222
Colour performance Isotra System Decoral 2 at extra charge (cover box, guiding rail, guiding rail holder, head + bottom rail)
-
ISD500
-
ISD510
-
ISD600
-
ISD610
-
ISD620
-
ISD630
-
ISD640
-
ISD700
Hereby stated colors are only indicative. If you want to see the color in real we recommend to visit one of our business partners where you can ask for physical swatch. We cannot accept claims for inappropriately chosen color according to electronic sampler.
Cetta 80 construction versions
Slim system
- fulfils requirements for low roll height,
- specific folding of slats (side alternative overlap of neighbouring slats) while keeping the option of guiding through bars
- suitable solution for assembly in the case of insufficient space for the roll.
Comparison of heights of the rolls for Cetta 80 and Cetta 80-Slim
Type of blind | Height of the blind (mm) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
500 | 600 | 700 | 800 | 900 | 1000 | 1100 | 1200 | 1300 | 1400 | 1500 | 1600 | 1700 | 1800 | 1900 | 2000 | 2100 | 2200 | |
Cetta 80 | 130 | 140 | 145 | 155 | 155 | 165 | 170 | 180 | 185 | 190 | 195 | 205 | 210 | 215 | 225 | 230 | 235 | 240 |
Cetta 80 slim | 125 | 135 | 135 | 145 | 150 | 155 | 160 | 165 | 170 | 180 | 180 | 190 | 195 | 195 | 205 | 205 | 215 | 220 |
Type of blind | Height of the blind (mm) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2300 | 2400 | 2500 | 2600 | 2700 | 2800 | 2900 | 3000 | 3100 | 3200 | 3300 | 3400 | 3500 | 3600 | 3700 | 3800 | 3900 | 4000 | |
Cetta 80 | 250 | 255 | 265 | 265 | 275 | 280 | 290 | 295 | 300 | 305 | 315 | 320 | 325 | 335 | 340 | 345 | 350 | 360 |
Cetta 80 slim | 225 | 230 | 230 | 240 | 250 | 250 | 260 | 265 | 270 | 275 | 280 | 285 | 290 | 295 | 300 | 305 | 310 | 320 |
Duo system
- enables different level of tilting of the slats of the upper and lower part of the blind at the same time
- ensures greater shading variability,
- suitable solution for administrative buildings, training rooms and conference halls.
Flexi system
- low roll height is achieved by using slats without longitudinal folding.
- suitable solution for assembly in the case of insufficient space for the roll.
Drawing of Cetta 80 Flexi
Upper profile | Lower profile | Lamella | Side Guidance | Ladder | Textile strip |
|||
---|---|---|---|---|---|---|---|---|
Steel Wire | Guiding Channel | |||||||
Business name Dimensions (mm) Material |
P 001 56 × 58 Fe ![]() |
P 001/2 58 × 60 Al ![]() |
P 012/3 80 × 13 Al ![]() |
P 309 0,42 × 80 Al ![]() |
P 501 ø 2,2 Fe/PVC |
See Technical Manual | P 030 72 × 85 PES |
P 531 P 531/1 6 × 0,28 PES |
Colour | Standard: galvanized sheet Other RAL sprayed DECORAL* |
Standard: satin anodized sheet Other RAL sprayed DECORAL* |
According to the actual sampler from ISOTRA a.s. |
grey black |
Standard: Other RAL sprayed |
grey black |
grey black |
*maximum dimension 4000 mm
Windstabil
- Exterior blind with higher wind resistanse class
Supportive guiding wires
Blind width (mm) | Supportive guiding wires |
up to 1499 | 2 pcs (fixed to the side guiding rail) |
1500 – 1999 | 2 pcs (fixed to the side guiding rail + 1 pcc in the middle) |
2000 - 3000 | 2 pcs (fixed to the side guiding rail + 2 pcs in the middle) |
Wind resistance table
Essential characteristics | Performance | ||||||||||||
Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 3 000 | 3 000 < L <= 4 000 | 4 000 < L <= 4 500 | 4 500 < L <= 5 000 | 5 000 < L <= 5 400 | |||||||
Standard EN/Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | |
Wind resistance class | 5 | 8 | 4 | 7 | 3 | 6 | 2 | 5 | 1 | 4 | 0 | 3 | |
Max. wind speed vmax (km/h) | 74 | 61 | 49 | 38 | 28 | 19 | |||||||
Max. effective height wing | Hmax = 2500 mm | ||||||||||||
Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 3 000 | 3 000 < L <= 4 000 | 4 000 < L <= 4 500 | 4 500 < L <= 5 000 | 5 000 < L <= 5 400 | |||||||
Wind resistance class | 4 | 7 | 3 | 6 | 2 | 5 | 1 | 4 | 0 | 3 | 0 | 2 | |
Max. wind speed vmax (km/h) | 61 | 49 | 38 | 28 | 19 | 11 | |||||||
Max. effective height wing | Hmax = 4000 mm | ||||||||||||
Additional thermal resistance ΔR | 0,08 (m2.K/W) | ||||||||||||
Total solar energy transmittance gtot | 0,032 - 0,094 (according to chosen slat colour)* |
Assembly options
Basic types of assembly
- Assembly into created pocket (ceiling/wall)
- Assembly into reveal on the window frame (ceiling/wall)
- Assembly on expanding window profile (ceiling/wall)
These three types of assembly can be in two versions: cover box visible, cover box incorporated into heat-insulation system or peripheral shell.
Specific assembly
- Self-bearing variant (fixation of the blind on guiding bars)
- Façade variant (round cassette; assembly on the façade)
- Assembly into Heluz lintel (built-in guiding bars)
- Assembly into Porotherm lintel (recommended for separate constructions)
- It is necessary to consider assembly into a lintel in the plans for a family house.
- The self-supporting blind with packet of slats outside the head rail
Sloped Blind Cetta 80F TE
- Solution for window screening with asymmetric shapes(upper frame is not horizontal but inclined under a specific angle)
- Slats copy the upper frame angle, and are parallel with it
- Aluminium slats are guided in steel wire
- Special mechanism which balances the different lengths of textile belts during the blind movement up and down
- The botrom rail is telescopic and it is used for balancing the different width of the blind in the lower position (window width) and the upper position (length of the window inclined part)
- Only motor kontrol
- Blind with low packet height using slats without lengthwise fold
Head Rail | Bottom Rail | Slat | Side Guidance | Ladder | Textile tape | ||
---|---|---|---|---|---|---|---|
Steel wire | |||||||
Commercial name Dimension (mm) Material |
P 001/2 58 × 60 Al ![]() |
P 012/6 + P 012/7 21 × 80 ![]() |
80 × 0,42 Al ![]() ![]() |
P 036 ø 3,2 Fe/PVC See Technical Manual |
P 30/4 P30/5 P30/6 P30/7 104 × 85 74 × 85 93,5 × 85 83 × 85 PES |
RHD 09 6 mm PES |
|
Color | Standard: natural (Al profil) Other RAL colors sprayed |
Standard: anodized aluminium Other RAL colors sprayed |
According to current ISOTRA a.s. scheme | According to current ISOTRA a.s. scheme |
grey | grey |
Non-standard dimensions are not produced.
Standard Dimensions
minimum width (mm) |
maximum width (mm) |
maximum height (mm) |
maximum guaranteed area (m2) |
max. angle (mm) |
---|---|---|---|---|
600 |
2500 |
4000 |
7 |
50° |
The self-supporting blind with packet of slats outside the head rail Bravo
Guaranteed dimensions for Cetta 80 blinds Bravo
BRAVO | Widht (mm) | Height (mm) | Guaranteed area (m2) | ||
---|---|---|---|---|---|
min. | max. | min. | max. | max. | |
without insect screen | 600 | 3500 | 500 | 3000 | 10,5 |
with insect screen | 720 | 1800 | 500 | 2500 | 3 |
The maximum height of blind, which the box of 210 mm is suitable for
Blind typ | Blind height (mm) |
Cetta 60 Flexi | 1900 |
Cetta 65 | 1900 |
Cetta 80 | 2200 |
Cetta 80 Flexi | 3000 |
Cetta 80 Slim | 2600 |
Cetta 100 Flexi | 3300 |
Setta 65 | 1900 |
Setta 90 | 2700 |
Zetta 70 | 2100 |
Zetta 90 | 2500 |
The self-supporting blind Viva
Guaranteed dimensions for Cetta 80 blinds Viva
VIVA | Widht (mm) | Height (mm) | Guaranteed area (m2) | ||
---|---|---|---|---|---|
min. | max. | min. | max. | max. | |
without insect screen | 600 | 4000 | 500 | 3000* | 10,5 (motor) |
with insect screen | 720 | 1800 | 500 | 2500* | 3 |
The maximum height of blind, which the box of 300 mm is suitable for
Blind typ | Blind height (mm) |
---|---|
Cetta 60 Flexi | 3500 |
Cetta 65 | 2400 |
Cetta 80 | 2800 |
Cetta 80 Flexi | 3000 |
Cetta 80 Slim | 3000 |
Cetta 100 Flexi | 4000 |
Setta 65 | 2400 |
Setta 90 | 3000 |
Zetta 70 | 2600 |
Zetta 90 | 3000 |
Cetta 80 a Cetta 80-Flexi into a lintel
Guaranteed dimensions for Cetta 80 and Cetta-Flexi blinds assembled into a lintel
- minimum width: 600 mm
- maximum width: 3,850 mm
- maximum height: 1,700 mm (Cetta 80), 4,000 mm (Cetta 80 – Flexi – wire), 2,800 mm (Cetta 80 – Flexi – guiding channels), 2,000 mm (Cetta 80 Slim)
- maximum area: 8 m2
Wind resistance
Wind resistance tests performed by Centrem stavebního inženýrství, a.s. in Zlín according to ČSN EN 13659.
Cetta 80 - guiding rope
Essential characteristics | Performance | ||||||||||||||
Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 3 000 | 3 000 < L <= 4 000 | 4 000 < L <= 4 500 | 4 500 < L <= 4 800 | 4 800 < L <= 5 000 | 5 000 < L <= 6 000 | ||||||||
Standard EN/Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | |
Wind resistance class | 3 | 6 | 2 | 5 | 1 | 4 | 0 | 3 | 0 | 2 | 0 | 1 | 0 | 0 | |
Max. wind speed vmax (km/h) | 49 | 38 | 28 | 19 | 11 | 5 | 1 | ||||||||
Max. effective height wing | Hmax = 2500 mm | ||||||||||||||
Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 3 000 | 3 000 < L <= 4 000 | 4 000 < L <= 4 500 | 4 500 < L <= 4 800 | 4 800 < L <= 5 000 | 5 000 < L <= 6 000 | ||||||||
Wind resistance class | 2 | 5 | 1 | 4 | 0 | 3 | 0 | 2 | 0 | 1 | 0 | 0 | 0 | 0 | |
Max. wind speed vmax (km/h) | 38 | 28 | 19 | 11 | 5 | 1 | 0 | ||||||||
Max. effective height wing | Hmax = 4000 mm | ||||||||||||||
Additional thermal resistance ΔR | 0,08 (m2.K/W) | ||||||||||||||
Total solar energy transmittance gtot | 0,032 - 0,094 (according to chosen slat colour)* |
Cetta 80 - guiding channel
Essential characteristics | Performance | ||||||||
Wind resistance | Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 3 000 | 3 000 < L <= 4 000 | 4 000 < L <= 4 500 | ||||
Standard EN/Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | |
Wind resistance class | 4 | 7 | 3 | 6 | 2 | 5 | 1 | 4 | |
Max. wind speed vmax (km/h) | 61 | 49 | 38 | 28 | |||||
Max. effective height wing | Hmax = 4000 mm | ||||||||
Width of construction hole L (mm) | 4 500 < L <= 5 000 | 5 000 < L <= 5 500 | 5 500 < L <= 5 800 | 5 800 < L <= 6 000 | |||||
Wind resistance class | 0 | 3 | 0 | 2 | 0 | 1 | 0 | 0 | |
Max. wind speed vmax (km/h) | 19 | 11 | 5 | 1 | |||||
Max. effective height wing | Hmax = 4000 mm | ||||||||
Additional thermal resistance ΔR | 0,08 (m2.K/W) | ||||||||
Total solar energy transmittance gtot | (according to chosen slat colour)* |
Cetta 80 Flexi - guiding rope
Essential characteristics | Performance | ||||||||||||||
Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 2 500 | 2 500 < L <= 3 000 | 3 000 < L <= 3 400 | 3 400 < L <= 3 800 | 3 800 < L <= 4 000 | |||||||||
Standard EN/Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | |||
Wind resistance class | 2 | 5 | 1 | 4 | 0 | 3 | 0 | 2 | 0 | 1 | 0 | 0 | |||
Max. wind speed vmax (km/h) | 38 | 28 | 19 | 11 | 5 | 1 | |||||||||
Max. effective height wing | Hmax = 2500 mm | ||||||||||||||
Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 2 500 | 2 500 < L <= 3 000 | 3 000 < L <= 3 400 | 3 400 < L <= 3 800 | 3 800 < L <= 4 000 | |||||||||
Wind resistance class | 1 | 4 | 0 | 3 | 0 | 2 | 0 | 1 | 0 | 0 | 0 | 0 | |||
Max. wind speed vmax (km/h) | 28 | 19 | 11 | 5 | 1 | 1 | |||||||||
Max. effective height wing | Hmax = 4000 mm | ||||||||||||||
Additional thermal resistance ΔR | 0,08 (m2.K/W) | ||||||||||||||
Total solar energy transmittance gtot | 0,032 - 0,094 (according to chosen slat colour)* |
Cetta 80 Flexi - guiding channel
Essential characteristics | Performance | ||||||||||||
Wind resistance | Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 3 000 | 3 000 < L <= 4 000 | 4 000 < L <= 4 500 | ||||||||
Standard EN/Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | 13659 | Beaufort | |||||
Wind resistance class | 2 | 5 | 1 | 4 | 0 | 3 | 0 | 2 | |||||
Max. wind speed vmax (km/h) | 38 | 28 | 19 | 11 | |||||||||
Max. effective height wing | Hmax = 4000 mm | ||||||||||||
Width of construction hole L (mm) | 4 500 < L <= 5 000 | 5 000 < L <= 6 000 | |||||||||||
Wind resistance class | 0 | 1 | 0 | 0 | |||||||||
Max. wind speed vmax (km/h) | 5 | 1 | |||||||||||
Max. effective height wing | Hmax = 4000 mm | ||||||||||||
Additional thermal resistance ΔR | 0,08 (m2.K/W) | ||||||||||||
Total solar energy transmittance gtot | 0,032 - 0,094 (according to chosen slat colour)* |
Sloping Cetta 80F TE
Essential characteristics | Performance | ||||||||
Wind resistance | Width of construction hole L (mm) | L <= 2 000 | 2 000 < L <= 2 500 | ||||||
Standard EN/Beaufort | 13659 | Beaufort | 13659 | Beaufort | |||||
Wind resistance class | 2 | 5 | 1 | 4 | |||||
Max. wind speed vmax (km/h) | 38 | 28 | |||||||
Max. effective height wing | 2 500 | ||||||||
Width of construction hole L (mm) | 2 500 | 2 500 | |||||||
Wind resistance class | 1 | 4 | 0 | 3 | |||||
Max. wind speed vmax (km/h) | 19 | 11 | |||||||
Max. effective height wing | 4 000 | ||||||||
Additional thermal resistance ΔR | 0,08 (m2.K/W) | ||||||||
Total solar energy transmittance gtot | 0,032 - 0,094 (according to chosen slat colour)* |
Viva
Essential characteristics | Performance |
---|---|
Wind resistance | Class 3, 4 (according to type slat) |
Additional thermal resistance ΔR | 0,08 (m2.K/W) |
Total solar energy transmittance gtot | 0,032 - 0,094 (according to select slat color)* |
Download
- Exterior blinds
- Technical manual
- Measurement and assembly manual
- Control and maintenance manual
- Order form Facade blinds
- Order form Windstabil
- Order form two headrails
- Order form Cetta 80F TE
- Order form
- Order form Emergency
- Order form Windstabil
- Order form – shaped blinds
- Order form Packet slat
- Order form Viva – preparation
- Order form Front covers
- Order form Viva and Bravo
Are you interested in this product? Do you have any questions?
We would like to answer your questions, please fill in the form below and we will respond within 3 working days.